A RAID array that loses a disk keeps running in a degraded state. Replacing the failed drive starts a rebuild: the controller reads the surviving disks and reconstructs the missing data onto the new one. During that window the array has no redundancy left, and on some RAID levels the process takes days.
Knowing what drives rebuild time, and what can go wrong while it runs, changes how you plan capacity, which RAID level you choose, and what you do before you touch the failed disk.
For RAID 1 and RAID 10, the controller copies data from the surviving mirror to the new disk. That is a straightforward sequential read and write, so it is relatively fast.
For RAID 5 and RAID 6, the controller must read every stripe from the remaining disks, recompute parity, and write the reconstructed block to the replacement. That involves reading the full capacity of the array, not just the used space, which is why parity rebuilds take much longer than mirror rebuilds.
The figures below assume 7200 rpm drives, a healthy controller and light background load. Treat them as planning ranges, not promises.
| Array | Typical rebuild | Notes |
|---|---|---|
| 1 TB RAID 1 | 1 to 3 hours | Mirror copy, mostly sequential |
| 4 TB RAID 5 | 6 to 12 hours | Full-stripe reads plus parity |
| 8 TB RAID 5 | 12 to 24 hours | Long window with no redundancy |
| 8 TB RAID 6 | 18 to 40 hours | Two parity calculations per stripe |
| 8 TB RAID 10 | 4 to 8 hours | Copies from one mirror member |
A RAID array built from SSDs can finish far sooner, but the controller and the rebuild algorithm often become the bottleneck before the drives do.
The array is degraded for the entire rebuild. If another disk fails or is removed, the volume is lost. Two additional risks make this window more dangerous than the raw failure rate suggests:
This is why large RAID 5 arrays are increasingly replaced by RAID 6 or RAID 10, and why a rebuild should never be started without a current backup of the data that matters.
Qiling Disk Master can image the volume to an external drive while the array is still degraded, so the backup does not depend on the failing hardware.
Step 1. Connect a drive with enough capacity, launch Qiling Disk Master, open the Backup and Recovery tab and click Disk/Partition backup.

Step 2. Tick the RAID volume as the source and click the folder icon to choose a destination.

Step 3. Select the external drive as the destination folder and click OK.

Step 4. Click Proceed and let the image finish before you remove the failed disk. Verify that the image opens before starting the rebuild.

Every controller reports rebuild status differently. Look for a percentage, an estimated time and a media error counter in the RAID management utility or in storcli, megacli or the vendor tool. A rebuild that stalls at the same percentage for hours usually indicates a read error on a surviving disk, not a slow controller.
Do not run benchmarks, defragmentation or large copies during the rebuild. Keep the load low, watch the temperature and SMART values, and let the process finish before you change anything else.
Finally, remember that RAID protects against disk failure, not against deletion, encryption or corruption. The array still needs a separate backup that is not part of the same volume.
Yes, but performance drops and the window of risk stays open. Keep writes to a minimum and avoid workloads that stress all members at once.
It writes the full capacity once, which is a small part of a drive's rated workload. The bigger concern is the load on the surviving disks.
Stop writing to the array and restore from the backup. Rebuilding again on the same members rarely helps if a second disk is failing.